  • 无菌室净化工程的装修与使用方法
    来源: 浏览: 发布日期:2018-01-26
    无菌室在电子信息、半导体、光电子、精密制造、医药卫生、生物工程、航天航空、汽车喷涂等众多行业均有应用,并根据行业的精密与无尘要求,等级差别也较大。
    Asepsis room has been applied in many industries, such as electronic information, semiconductor, optoelectronics, precision manufacturing, medical and health, bioengineering, aerospace, automotive spraying and many other industries. According to the industry's precision and dust-free requirements, the level difference is also large.
    无菌室和缓冲间都必须密闭、室内装备的换气设备必须有空气过滤装置。在获得了无菌环境和无菌材料后,只有保持无菌状态,才能对某种特定的已知微生物进行研究。所以控菌能力和控菌稳定性是无菌室的核心验收指标。
    The asepsis room and the buffer room must be closed, and the ventilation equipment of the indoor equipment must have air filter. After the aseptic and aseptic materials are obtained, a specific known microorganism can be studied only by maintaining the aseptic state. Therefore, the ability to control bacteria and the stability of bacteria control are the core acceptance criteria in the asepsis room.
    无菌室净化工程的装修要求:
    The decoration requirements of asepsis room purification engineering:
    1、工作室应矮小、平整,面积只需4米2左右,高2.2-2.3米,内部装修应平整、光滑,无凹凸不平或棱角等。
    1, the studio should be small and smooth, the area only needs about 4 meters and 2, high 2.2-2.3 meters, interior decoration should be smooth, smooth, no bump or angle and so on.
    2、室内采光面积大,从室外应能看到室内情况。
    2. The indoor lighting area is large, and the indoor situation should be seen from the outdoor.
    3、为保证无菌室的洁净,无菌室周围需设缓冲走廊,走廊旁再设缓冲间,其面积可小于无菌室。
    3. To ensure the cleanliness of the asepsis room, a buffer corridor should be set around the asepsis room. The buffer room is set beside the corridor. The area can be less than that of the asepsis room.
    4、无菌室、缓冲走廊及缓冲间均设有日光灯及供消毒空气用紫外灯,杀菌紫外灯离工作台以1米为宜 ,其电源开关均应设在室外。
    4, asepsis room, buffer corridor and buffer room are equipped with fluorescent lamps and ultraviolet lamps for disinfection of air. The ultraviolet lamp is suitable for 1 meters away from the worktable, and the power switches should be located outside.
    5、无菌室与缓冲间进出口应设拉门,门与窗平齐,门缝要封紧,两门应错开,以免空气对流造成污染。
    5, the entrance and exit of the asepsis room and the buffer room should be set up, the door and the window are flat, the door seam should be sealed, the two doors should be staggered, so as to avoid the air pollution caused by the pollution.
    以上的先容,您了解了吗?如果您有不明白的地方,欢迎您的致电,大家全面为您先容,欢迎您的莅临参观哦。
    Do you know the above introduction? If you do not understand the place, welcome your call, we would like to introduce you in an all-round way, welcome to visit you.